Three versions of our high-quality AEE CEM dumps VCE file
We sell three versions of our high-quality products which satisfy different kinds of study demands: PDF version, Soft (PC Test Engine), APP (Online Test Engine). A part of candidates are interested in PDF version of CEM real dumps as they are accustomed to this simple and traditional learning method.
Questions and answers materials for these three versions of CEM premium VCE file are same. Also there are a part of candidates who like studying on computer or electronic products. Soft (PC Test Engine) of Certified Energy Manager (CEM) VCE files is for candidates who are used to learning on computer. It is installed on the Windows operating system and running on the Java environment. You can use practice test VCE any time to test your own exam simulation test scores. Our AEE CEM dumps VCE file boosts your confidence for real exam and will help you keep good mood in real test.
APP (Online Test Engine) of CEM real dumps has same functions with soft (PC Test Engine). This version is possessed of stronger applicability and generality. By contrast, Online Test Engine of Certified Energy Manager (CEM) exam VCE is more stable and the interface is more humanized.
7*24 online service support; Best and professional customer service
We have an complete online support system which is available for every candidate who is interested in AEE CEM dumps VCE file 7*24, and we will answer your query in time, you can ask us about the professionals and can also ask for AEE Certified Energy Manager (CEM) exam, we will offer you the best of solutions free of charge.
Instant Download: Our system will send you the CEM braindumps file you purchase in mailbox in a minute after payment. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
We are a team of certified professionals with lots of experience in editing AEE CEM dumps VCE file. Every candidate should have more than 8 years' education experience in this industry. We have rather a large influence over quite a quantity of candidates. Our CEM real dumps are honored as the first choice of most candidates who are urgent for clearing Certified Energy Manager (CEM) exams. With so many years' concentrated development we are more and more mature and stable, there are more than 9600 candidates choosing our AEE CEM dumps VCE file. We now have good reputation in this field. We are more than more popular by our high passing rate and high quality of our CEM real dumps. Our education team of professionals will give you the best of what you deserve.
AEE Certified Energy Manager (CEM) Sample Questions:
1. Thermal scans of electrical equipment are useful for:
A) Locating a loose electrical connection
B) Locating areas of high power factor
C) Reading current carrying capacity of installed conductors
D) Measuring the load on a refrigerant system
2. Which of the following is NOT a typical benefit of performance contracting from the building owner's perspective?
A) Maintenance services provided by the performance contractor can add value to the overall savings achieved
B) Net cash flow can be neutral or positive for the owner
C) The energy-service company can have a financial incentive to achieve projected savings
D) Performance contracting can provide access to external financing when the owner may not have sufficient equity for in-house financing for large projects
E) Performance contracting is a simple and quick process
3. A building has a 100 m² wall with an R-value of 14.4 (m²-C/W) in a climate with 3,500 heating degree days (HDD). The building heater is 85% efficient [based on the fuel's higher-heating value (HHV)]. The fuel cost is $5.00/GJ [based on the fuel's higher-heating value (HHV)]. What is the annual cost of the heat loss through the wall?
A) $10.56/yr
B) $14.44/yr
C) $16.22/yr
D) $12.35/yr
E) $22.56/yr
4. The temperature in an unconditioned mechanical room is found to typically be around 23°C warmer than ambient air. If the air intake of an air compressor located in the mechanical room is routed through a nearby wall so that ambient air is fed directly to the air compressor's intake, what impact can be expected on the air compressor's energy requirement?
A) Increase energy use by 7.6%
B) No measureable change in energy use
C) Decrease energy use by 7.6%
D) Increase energy use by 3.8%
E) Decrease energy use by 3.8%
5. Which type of single-phase alternating-current motor has the highest efficiency?
A) Permanent split-capacitor motor
B) Electronic-commutated motor
C) Shaded-pole motor
Solutions:
Question # 1 Answer: A | Question # 2 Answer: E | Question # 3 Answer: B | Question # 4 Answer: C | Question # 5 Answer: B |